판매

ISCO SAMPLER REFRIGERATOR 3700/6700FR

by 김기철 posted May 31, 2019
?

단축키

Prev이전 문서

Next다음 문서

ESC닫기

크게 작게 위로 아래로 댓글로 가기 인쇄
ISCO SAMPLER REFRIGERATOR 3700/6700FR
수량 1SET
상태양호 작동양호
Isco 3700FR Refrigerated Sampler Specifications
Ordering Information
Refrigerator
Height 47 in. 125 cm
Width 26 in. 66 cm
Depth 26 in. 66 cm
Weight (dry) 160 lbs. 73 kg
Exterior Materials Resin transfer molded fiberglass with UV resistant
fiberglass gel coat
Frame Construction Stainless steel
Corrosion Protection
Condenser Powder coated with polyester
Compressor Enamel paint
Evaporator Powder coated with food grade epoxy
Refrigeration tubing Polyester tubing or phenolic resin
Insulation Environmentally safe non CFC foam
Top 3 in. 7.6 cm
Sides 1.5 in. 3.8 cm
Thermal Resistance Factor R-16
Typical Recovery Time 5 minutes
Recovery time is defined as the time for the internal air temperature to return to 39°F (4°C) with the
refrigerator running and set at 39°F (4°C) and the door has been opened for one minute. The door has
been opened at least 4 minutes after the compressor has turned on.
External Temperature 75°F 24°C
Sample Temperature
Set-point Range 32° to 46°F 0° to 8°C
Sample Temperature
Set-point Accuracy (at 25°C) ±1.8°F ±1°C
Refrigerant Type R-134a 1 1 1 2-tetrafluoroethane CH2FCF3
Compressor 1/5 horsepower
Power Requirements 120V 60 Hz 240V 50/60 Hz
Current Draw
Running 3.5 amp @ 120V 1.75 amp @ 240V
Starting 17 amp @ 120V 8.5 amp @ 240V
Stalled Compressor 21 amp @ 120V 10.5 amp @ 240V
Compressor Protection
Safety cutout at 221°F 105°C
Heaters 3 automatically controlled
Heater Capacity 60 watts (evaporator heaters); 30 watts (compressor heater)
Software
Sample Frequency Selection 1 minute to 99 hours 59 minutes in 1 minute increments
Non-uniform times in minutes or clock times
1 to 9999 flow pulses
Programmable
Sample Volumes 10 to 9990 ml in 1 ml increments
Liquid Presence Detector Non contacting patented LD90
Sample Retries If no sample is detected up to 3 attempts; user selectable
Rinse Cycles Automatic rinsing of suction line up to 3 rinses for
each sample collection
Sample Distribution
Samples per Bottle 100 maximum
Bottles per Sample Up to number of bottles in set
Program Storage 3 sampling programs
Programming Modes Time non-uniform time flow and STORM
Controller Diagnostics Tests for RAM ROM pump display and distributor
Controller
Weight 11 lbs. 5.9 kg
Dimensions 10 x 12.5 x 10 in. 26 x 32 x 25 cm
Operational Temperature 32° to 120°F 0° to 49°C
Enclosure Rating NEMA 4X 6 IP67
Program Memory Non-volatile ROM
Flow Meter 5 to 15 volt DC pulse or 25 millisecond isolated
Signal Requirements contact closure
Pump
Intake Suction Tubing
Length 3 to 99 ft. 1 to 30 m
Material Vinyl or Teflon
Inside Dimension ⅜in. or ¼in.
Pump Tubing Life Recommended 500000 pump counts
Maximum Suction Lift 26 ft. 7.9 m
Typical Repeatability ±10 ml
Typical Line Transport Velocity
at head heights of:
3 ft. (0.9 m) 2.9 ft./s 0.88 m/s
10 ft. (3.1 m) 2.5 ft./s 0.76 m/s
15 ft. (4.6 m) 1.9 ft./s 0.58 m/s
Description Part
참고자료 http://www.isco.com/products/products2.asp?PL=20120&image=Samplers3.jpg
메뉴얼 http://www.isco.com/products/manuals1.asp?PL=20120&GP=20120
연락처 011-354-6248